Drafting Studio

Electrical Design

Photometric Design

Point-by-point photometric studies to prove your lighting meets code and design targets — interior, parking, site and facade — delivered as a calc grid and report.

How it works

From upload to permit-ready set

5 business days — start to delivery

  1. 01

    Upload & confirm

    Send your plans and scope; we confirm a fixed price and date.

  2. 02

    Document review

    We review inputs and flag anything missing up front.

  3. 03

    2D drafting

    Your set is drafted in AutoCAD to code and your CAD standard.

  4. 04

    Quality check

    Internal QC against the code and your requirements.

  5. 05

    Delivery

    Layered DWG + plotted PDF, with two free minor revisions.

IES-Standard Output

Grids and ratios computed per IES methodology.

Fast Turnaround

Most sets delivered in 3–7 business days, rush options available.

All Building Types

Interior, parking, site, facade and sports lighting.

Two Free Revisions

Included minor revisions so the set lands right the first time.

What's included

Every photometric design package is delivered as a layered 2D AutoCAD set.

  • Point-by-point footcandle calculation grid
  • Average / min / max & uniformity ratios
  • Fixture layout with IES types
  • Code / ordinance compliance summary
  • Light trespass & spill check (site)
  • Photometric plan (DWG + PDF) & report
.dwg.pdf.dxf (on request).xlsx / .pdf reports
Documents required
  • Floor plan or site plan (DWG or PDF)
  • Fixture IES files or model numbers
  • Target footcandle criteria / applicable code
  • Mounting heights
What's not covered
  • Fixture supply or procurement
  • PE stamping
  • On-site light meter readings
  • Utility rebate filing
Delivery standards

Drafted to current US codes and your CAD standard, QC-checked, with two free minor revisions. Ready for your engineer to review and stamp.

Prove the light levels

A photometric study models illuminance across a space using manufacturer IES files and shows the footcandle grid, average/min/max, uniformity ratios, and compliance with the applicable code or dark-sky ordinance. We deliver the calculation plan plus a summary report suitable for AHJ or client review.

Where it is used

Parking lots and garages, building exteriors and facades, sports courts, warehouses, retail and restaurant interiors, healthcare, and any project with a minimum-illuminance or light-trespass requirement.

FAQ

Photometric Design questions

Have a question or scope?

Ask about photometric design or start a fixed quote. We reply within one business day.